Concrete Thermal Resistance Temperature Rise Measurement Apparatus
Contents of page
Outline of Product Technology
Product number: MIT-686-3-01,MIT-686-3-02
The temperature of the constant temperature chamber is controlled to be risen immediately according to the rise of the heat of hydration of the concrete in the container, so that the temperature of the concrete in the container and constant temperature chamber are kept the same.
The temperature of the constant temperature chamber is controlled to be risen immediately according to the rise of the heat of hydration of the concrete in the container, so that the temperature of the concrete in the container and constant temperature chamber are kept the same.
Product Outline
Specifications
Temperature | 10 〜 +80℃ |
---|---|
Control accuracy | ±1℃ (temperature difference between specimens inside and outside) |
Container for specimen | φ 400 x H 400 mm / 50 L |
Type | MIT-686-3-01 type : One-gang type MIT-686-3-02 type : Two-gang type |
Power supply | Three phase 200 V 15 A |